Does a basement crawlspace require HVAC outlets?

Our 1960's crawlspace (has a poured concrete floor) has 2 outlets from our ductwork. We're in Toronto. I'm wondering if these are required or not?

Here is one of the outlets. I like the high tech styrofoam cover inside:


The crawlspace floor and walls and ceiling are uninsulated. The walls are concrete block, floor joists exposed.

Will need to do some research to find out.

Thus far, one HVAC pro from Missouri of all places, suggested to permanently seal the crawlspace ducts. He suggested putting a 4 mil. plastic vapour barrier on the crawlspace floor. I'll research that as well.

More investigation on our ductwork

I have been trying to investigate what the best approach is for addressing our low airflow duct issue in all of our upstairs bedrooms. I contacted an HVAC guy, who is more of a ductwork installer, to come and look at the problem. Naturally, his recommendation was just ductwork related! Shannon over at http://www.house-improvements.com/ also feels that it will improve things, and I trust his advice.

I know that it will. But, will that be the best bang for the buck? I'm not sure. Are there other options that HVAC specialists might know about? I'm not sure also. So, before I call in more contractors, I thought I'd try to use the collective brains of the internet for this one. So I setup an account at http://hvac-talk.com/.

http://hvac-talk.com/ is a site for HVAC professionals to chit chat with, and they also help out homeowners with questions. It's also very active for an HVAC site, so I thought that I might get some responses fairly quickly. And already I did. Essentially, the HVAC pros need more information. So I provided more information to them at http://hvac-talk.com/vbb/showthread.php?1402171-Should-I-address-this-ductwork.

Shophound agreed with Shannon and Larry, the ductwork specialist who came and looked at the issue. Shophound said "that duct configuration would be an airflow killer in ANY installation. Especially at the 90° elbow with no turning vanes and a poor radius on the inside corner. Some folks forget that moving air has momentum: that is one contributor to turbulence within a duct. Within that elbow I can visualize all manner of turbulence as air exiting the transition must suddenly change direction."

Udarrell said "That duct configuration is an absolute nightmare airflow killer..."

Good! So far, the pros are in agreement, the ductwork is a terrible design.

Wahoo suggested that more information is needed. So, I provided more information to him. For reference, I'm including what I provided to him below:

Our furnace is a high efficiency furnace. Manufacture date was Oct 2011. It looks like an "International Comfort Products" model number G9MVT0801716A1. I don't know anything about furnaces, but it says:
- Input BTU/HR HI = 80,000, LO = 52,000
- Ouput BTU/HR HI = 78000, LO = 50,000

Air filter - using a passive filter, 20x25x5", manufacturer is Duststop. Just installed it about 1 1/2 months ago.

Our house is a 2,300 sq ft above grade. Basement is about 700sq ft at 7' height, then about another 700sq ft at 3 1/2' height (in the crawlspace area). The furnace is installed in the bungalow of our split level. The bungalow side of the house above grade is about 700 sq ft. The 2 level side of the house is the other 1,600 sq ft above grade.

The furnace has 2 main runs leaving it. The ductwork to the bungalow area of the house is 12 x 8". The ductwork to the 2 level side of the house, that goes through the concrete block, is 16 x 8".

Here are pictures to help with the research:







Thursday, September 19, 2013

Met with K H Davis Engineering consultants today to review main floor sloping issue

They arrived to look at the sloping on my main floor. Since I removed the ceiling in our basement, the joists are very clear to be seen. The engineer reviewed the floor sloping issue, and took a bunch of measurements.

He did say that the joists all appear to meet code based on his measurements, and that the main floor sloping issue isn't going to cause the house to fall apart. So I was happy to hear that.

He will get back within a week or so, with details of exactly what is the issue, and what options are available to fix it. I'm excited, but at the same time hoping that the options won't be incredibly costly! He did mention that joist sistering will likely be one of the recommended options. Fingers crossed.


Should we address the ductwork?

There are 2 things in our ductwork that I'd like to address.

One is that, our upstairs bedrooms have very low airflow coming out of the ducts. We have a split level house, and the furnace blower is in the bungalow part of the house. The basement in the bungalow part of the house has a 7' high ceiling. The basement in the two storey party of the house has about a 3 1/2' high ceiling.

The furnace feeds the upstairs bedrooms through ductwork that goes through the concrete block as shown in these photos (apologies for the poor quality pics):




I had an HVAC guy come yesterday to suggest that there is a lot of airflow lost before the air even gets past the concrete block, due to the way the ductwork angles up from the furnace, and then angles down at about a 45 degree angle. He suggested that smoothing this out will significantly improve airflow, in addition to applying mastic on all duct joints. Right now it's quite obvious that the old foil tape, and complete lack of sealant in other ductwork joints, is probably contributing to loss of airflow.

At this point I need to validate the theory that the ductwork coming out of the furnace, and then angling down, is contributing to a large loss of airflow. I'll get some additional perspectives on the issue.

Edit: Shannon over at house-improvements.com agreed 100% with the HVAC guy who came to the house. As I trust Shannon's advice a ton, I feel good about making this improvement and will likely go ahead with doing it.

The second issue is about rerouting the ductwork in the basement. I'll post about that one separately.

Tuesday, September 17, 2013

One 20 yard bin down!

This past weekend was a big milestone for me...I filled my first bin! This was a big milestone for me. For me, it was a pretty significantly physical effort to do this (I'm out of shape!) and on top of that, I was able to do this around a very busy work and family schedule. Imagine having a 6 month old and a 2 1/2 year old toddler. That does not equate to free time for basement demolitions!

I called the bin rental company back, Remove My Junk, and they came the same day to pick it up! I'm still waiting on the bill though. Hopefully it doesn't rain before they weigh it!

Address mechanical and infrastructure issues while you have the chance!

As we are still in demolition mode with our basement renovation, it gives us the opportunity to address issues that we might not otherwise. For example, on our main floor, we have some serious floor sloping in one area. The main floor is right atop our basement. Now that our basement ceiling is fully removed and exposed, I thought that this would be the perfect time to investigate the cause of the slope, and possible remedies.

My gut feeling would be that our basement posts need to be raised, or we need additional support in the basement for the main floor, to remedy it. At first I went to Shannon from http://www.house-improvements.com. Shannon really knows his stuff, and is extremely helpful. I started a thread on Shannon's forum asking for his advice. Shannon suggested that I look into a few things, which I have, but at this point I'm just throwing darts in the dark. It would really be a tedious and trial-and-error research process.

Since I don't want to bombard Shannon's with all of this trial and error stuff (the guy definitely commits a lot of extracurricular time to his online presence and does contracting), I started to think that maybe a structural engineer would be the better way to go from here.

So I contacted K.H Davis Engineering Consultants in Toronto (aka Ken Davis Structural Engineering on homestars.com). I contracted them out to come to our house this Thursday to look at our main floor sloping issue. For $450 + HST, they come onsite, and research the issue. Within a week or two they then deliver you documents that detail the steps to remedy the issue. I'm hoping that this will be money well spent.

The other issue that I have the opportunity to address is our incredibly low airflow from our bedrooms ducts. We live in a split level home that was made in the 1960's. Split levels are well known for temperature variance between floors, but in our case, the issue is exacerbated because we hardly get any airflow coming out of our top floor bedroom ducts! In addition, it might be nice to move the basement ductwork around a bit, to gain more headroom where it matters more. More to come on that.

Monday, September 16, 2013

Homestars - the customer is sometimes wrong

As a prudent DIYer, I try to research contractors to find ones that are a good fit for me. Part of my research lately has been to use homestars, a Canadian contractor review website for homeowners. I've had luck finding great contractors through homestars. But after using homestars for some time now to research contractors, I have found that "buyer beware" is very important when looking at contractors on homestars.

One such company that I found on homestars is called "Furnace and AC Direct", based out of Mississauga. They have "87 reviews" at this time, and a perfect 10 / 10 record. WOW! They must be the gods of furnace and AC work! Have a look for yourself:


The business owner, Khuram Zaki, must be a fabulous person. But, take a look at some of Khuram's reviewers. Many are "flagged for verification". Flagged for verification?!? Look at the bottom of page 1 of Khuram's reviews as of today:




Page 2 has even more! Now, without being judgmental, I will say that this is suspicious. Maybe another contractor paid people to give bad reviews of Khuram's company. That would be sad if contractors try to cannibalize one another's business this way. However, maybe Khuram is abusing the homestars system by flagging all of his customers that didn't provide a 10 out of 10 feedback score. 

For this reason, it looks especially suspect that Khuram is abusing the homestars system, making it appear that homestars is a system very biased toward the contractor. Which makes sense, since contractors pay homestars to be listed on the homestars service. Which is also unfortunate, since homestars is meant to be a research tool for homeowners to find the next great contractor. 

Hopefully homestars is able to evolve into a system less biased towards its contractors over time. Until then, be mindful of all of those 10 out of 10 reviews!